Description
The machine consists of a load frame and motorized pumping unit.
The lower platen has two rollers, the distance between which is adjustable.
The upper platen has also roller. Micro-processor based Digital Load Indicator to indicate applied load is fitted in the Pumping unit. The Pumping unit is separate electrically operated, housed in a cabinet. On/Off switch and a slow/fast lever to control rate of loading are fitted on the front panel of the pumping unit.
A micro switch and relay fitted inside the Digital Load indicator to protect
the unit from over loading.
- Max. Tile size 660 X 660mm
- Direct reading of total applied load in KN
- Direct reading of Flexural strength in N/mm2 – No calculation required
- Peak hold facility
- RS 232 interface (Optional – at extra cost)
- Direct analytical reports on computer (Optional)
- Auto generation of load/time graph. (Optional)
- Overload safety cut out
- Password protected Calibration to prevent Un authorized manipulation
Type of Pumping: Electrical
- Loading Range: 100 KN
- Least Count: 0.1 KN
- Optional Accessories at extra cost: 1) PC link software
- 2) Wireless PC link software